ver : a_7 update : 2018.06.06 ac -dc ite & medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) mtc30-5s MTC30-12S mtc30-15s mtc30-24s max output wattage (w) 25w 30w 30w 30w input voltage 90-264 vac or 120-370 vdc frequency (hz) 47-440 hz current (full load) 650 ma max. (115 vac) / 400 ma max. (230 vac) inrush current (<2ms,cold start) 30 a max. (115 vac) / 60 a max. (230 vac) leakage current < 0.1ma / 264 vac (touch current) no load input power (<240 vac) <0.15w external fuse (recommend) 3.15 a slow blow type output voltage (v.dc.) 5v 12v 15v 24v voltage accuracy 2% current (ma) max 5000 2500 2000 1250 line regulation (ll-hl) (typ.) 0.5% load regulation (10-100%) (typ.) 1% maximum capacitive load (at 230 vac) 6800uf 1600uf 1200uf 470uf ripple & noise (max.) (note 1) 100mvp-p 150mvp-p 150mvp-p 240mvp-p efficiency (at 230 vac) 84% 89% 86% 86% hold-up time 10 ms min. protection over power protection hicc up technique, auto-recovery over voltage protection zener diode clamp short circuit protection hiccup mode, indefinite (automatic recovery) isolation input-output (v.ac) 4000v environment operating temperature -40c?+80c (with derating) storage temperature -40c?+90c max case operating temperature 84c temperature coefficient 0.05%/c altitude during operation 5000m humidity up to 95% rh mtbf >250,000 h @ 25c (mil-hdbk-217f) atmospheric pressure 70 kpa to 106 kpa physical dimension (l x w x h) 2.52 x 1.8 x 0.93 inches ( 64.1 x 45.6 x 23.5 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 135 g cooling method free air convection key features ? switching power module for pcb mountable ? fully encapsulated plastic case ? universal input range 90-264vac ? regulated output and low ripple and noise ? <0.15w no load input power ? isolation class ii ? ce, cb, ul, cul approval ? 3-year product warranty
ver : a_7 update : 2018.06.06 ac -dc ite & medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) mtc30-5s MTC30-12S mtc30-15s mtc30-24s safety approval cul / ul standard: ul 60950-1, can/csa c22.2 no. 60950-1-07 ansi/aami es60601-1 (2005 + c1:09 + a2:10), can/csa-c22.2 no. 60601-1 (2008), 2 x mopp cb standard: iec 60950-1:2005 (2nd edition) + am 1:2009 + am 2:2013 iec 60601-1:2005 (3rd edition) + corr. 1 (2006) + corr. 2 (2007) + am1 (2012) or iec 60601-1 (2012 reprint), 2 x mopp emc conducted and radiated emi en55011 class b (radi ation class a for mtc30 a2 series) ems en60601-1-2 4th edition note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. safety approvals cover frequency 47-63 hz. 3. that ?natural convection? is about 20lfm but is not equal to still air (0 lfm). 4. it's recommended to add varistor 14s471k at l / n input side in parallel. 5. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw mechanical dimension ( top view ) block diagram pin# single 1 ac in (n) 2 ac in (l) 3 -dc out 4 no pin 5 +dc out
ver : a_7 update : 2018.06.06 ac -dc ite & medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- derating screw terminal mtc30-a2 pin# single 1 ac in (n) 2 no connect 3 ac in (l) 4 no connect 5 -dc out 6 no connect 7 +dc out 8 no connect
|